    SVST TECHNOLOGY CO., LTD

    RCI9H2 for Neles™ ValvGuard™ VG9000

    Liên hệ
    RCI Card
    RCI Card
    Neles
    Còn hàng

    RCI9H2 is intended to be used together with the Neles ValvGuard VG9000H. It is needed when a 24 VDC output (DO) is used in the safety system. RCI9H2 is connected between the safety system and the field device VG9000H. The primary function of RCI9H2 is to convert a safety DO into a SIL 3 compatible 4-20mA current signal. RCI9H2 also provides relay outputs for monitoring the test and alarm status of the VG9000H.

     

    • Chia sẻ qua viber bài: RCI9H2 for Neles™ ValvGuard™ VG9000
    • Chia sẻ qua reddit bài:RCI9H2 for Neles™ ValvGuard™ VG9000

    RCI9H2 for Neles™ ValvGuard™ VG9000

    RCI9H2 is intended to be used together with the Neles ValvGuard VG9000H. It is needed when a 24 VDC output (DO) is used in the safety system. RCI9H2 is connected between the safety system and the field device VG9000H. The primary function of RCI9H2 is to convert a safety DO into a SIL 3 compatible 4-20mA current signal. RCI9H2 also provides relay outputs for monitoring the test and alarm status of the VG9000H.

     

    RCI9H2 is intended to be used together with the Neles ValvGuard VG9000H. It is needed when a 24 VDC output (DO) is used in the safety system. RCI9H2 is connected between the safety system and the field device VG9000H. The primary function of RCI9H2 is to convert a safety DO into a SIL 3 compatible 4-20mA current signal. RCI9H2 also provides relay outputs for monitoring the test and alarm status of the VG9000H.

    Features

    • 24 VDC input from ESD system
    • 4/20 mA output to VG9000H
    • Two status relays (test, alarm)
    • PST start via separate 24 VDC input
    • HART communication
    • Isolated Ex barrier
    • Up to SIL3 acc. to IEC 61508

    Benefits

    RCI9H2 for VG9000H provides reliable and safe status information of ESD valves for shutdown systems. Included isolated barrier eliminates additional component need in intrisically safe applications. 

    Applications

    • SIL 3 certified according to IEC 61508
    • HART communication
    • Status relays

    Specifications

      
    Input signal
    24 - 48 VDC
    Output signal
    4/20 mA
    Power supply
    24 - 48 VDC
    Communication
    HART
    Status relays
    Test and alarm
    Appvovals
    ATEX/IECEx Ex II (1) G [Ex ia Ga] IIC

    Tags

    RELATED PRODUCTS

    Emergency shutdown valves
    Liên hệ

    Emergency shutdown valves

    Reliable intelligent emergency shutdown (ESD) valves and actuators with Neles™ ValvGuard™ intelligent valve controllers improve your plant safety cost efficiently. In Neles we have combined our know-how of valves, actuators, safety standards (IEC61508/61511), applications, system operability and partial stroke test devices with intelligent prediction tools. Diagnostic information is presented understandably to enable planned maintenance of potentially failing valve assemblies before they have a chance to impact the process or safety.
    Neles™ ValvGuard™ VG9000 – intelligent safety solenoid
    Liên hệ

    Neles™ ValvGuard™ VG9000 – intelligent safety solenoid

    Neles ValvGuard is a top class intelligent safety solenoid with partial stroke testing features for emergency shutdown and venting valves. Based on the automatic PST and other diagnostics data, VG9000 increases safety and plant safety targets can be reached more economically than with other solutions.
    LCP9H for Neles™ ValvGuard™ VG9000
    Liên hệ

    LCP9H for Neles™ ValvGuard™ VG9000

    Local Control Panel (LCP) is designed for controlling the emergency isolation valve (ESD or ESV) locally nearby the valve via Neles ValvGuard VG9000 intelligent solenoid valve. LCP permits the emergency isolation valve to be closed (or opened) locally and permits the valve to be returned to the normal operating position when the trip initiators are normal (Manual Reset -function).